| Availability: | |
|---|---|
| Quantity: | |
TW350
KINGWIT
This product is designed for areas with fire safety design requirements, such as commercial spaces, hotels, office buildings, transportation hubs, high-rise residential buildings, schools, hospitals, factories, underground spaces, and emergency exits.
Color: White
Density (±0.05g/cm³): 1.42
Touch Dry Time: Approximately 60 minutes
Initial Crack Resistance (6h): No cracks
Sanding: Hand-sandable
Alkali Resistance (48h): No abnormalities
Water Resistance (96h): No abnormalities
Water Absorption (g/10min): 1.9
Washability (Number of Scrubs): 700 times without exposing the base
Dynamic Crack Resistance (Base Crack), mm: 0.06
Bond Strength, MPa:
Standard Condition: 0.64
Freeze-Thaw Cycle (5 times): 0.42
Volatile Organic Compounds (VOC), g/kg: 2
Total of Benzene, Toluene, Ethylbenzene, Xylene, mg/kg: Not detected
Free Formaldehyde, mg/kg: 24
Total Lead (Pb) Content, mg/kg: 21
The surface to be painted must be free from grease, dirt, and loose materials. Newly constructed walls must be fully dry, with moisture content below 14% and pH below 10. Unpainted wood or metal should be properly primed before application.
New concrete walls must cure for 30 days before painting.
Ensure that putty is not soft; once dry, smooth with fine sandpaper and dust off.
For repainting old walls, use a scraper to remove loose material, then sand to eliminate any flaky paint.
Fill in wall defects with appropriate putty.
Scrape off mold and sand the area to remove traces.
Apply a suitable mold removal solution and rinse with clean water, allowing it to dry thoroughly.
This product is designed for areas with fire safety design requirements, such as commercial spaces, hotels, office buildings, transportation hubs, high-rise residential buildings, schools, hospitals, factories, underground spaces, and emergency exits.
Color: White
Density (±0.05g/cm³): 1.42
Touch Dry Time: Approximately 60 minutes
Initial Crack Resistance (6h): No cracks
Sanding: Hand-sandable
Alkali Resistance (48h): No abnormalities
Water Resistance (96h): No abnormalities
Water Absorption (g/10min): 1.9
Washability (Number of Scrubs): 700 times without exposing the base
Dynamic Crack Resistance (Base Crack), mm: 0.06
Bond Strength, MPa:
Standard Condition: 0.64
Freeze-Thaw Cycle (5 times): 0.42
Volatile Organic Compounds (VOC), g/kg: 2
Total of Benzene, Toluene, Ethylbenzene, Xylene, mg/kg: Not detected
Free Formaldehyde, mg/kg: 24
Total Lead (Pb) Content, mg/kg: 21
The surface to be painted must be free from grease, dirt, and loose materials. Newly constructed walls must be fully dry, with moisture content below 14% and pH below 10. Unpainted wood or metal should be properly primed before application.
New concrete walls must cure for 30 days before painting.
Ensure that putty is not soft; once dry, smooth with fine sandpaper and dust off.
For repainting old walls, use a scraper to remove loose material, then sand to eliminate any flaky paint.
Fill in wall defects with appropriate putty.
Scrape off mold and sand the area to remove traces.
Apply a suitable mold removal solution and rinse with clean water, allowing it to dry thoroughly.
content is empty!
content is empty!